  • Primary scheme of high voltage thyristor soft start
    072021-12

    Primary scheme of high voltage thyristor soft start

    快盈500个人主页High voltage solid-state soft start cabinet is designed as cabinet structure. The cabinet frame is welded with 50 angle steel, which is firm and reliable. The cabinet is designed in the way of incomin···

  • Product introduction of high voltage soft start cabinet
    072021-12

    Product introduction of high voltage soft start cabinet

    快盈500个人主页High voltage soft start cabinet is the starting equipment of high voltage AC motor. It is a three-phase anti parallel thyristor assembly and its electronic control device connected between the power s···

  • Solution to the problem that the frequency of frequency converter does not go up
    072021-12

    Solution to the problem that the frequency of frequency converter does not go up

    The frequency of the frequency converter can't jump up. First, let's look at the no-load condition and don't connect the motor first.1. For a frequency converter, there are frequency range···

  • Soft starter input phase failure
    062021-12

    Soft starter input phase failure

    Soft starter input phase failure:(1) Check whether the incoming power supply and motor wiring are loose;(2) whether the output is connected to the load and whether the load matches the motor;(3) Use a···

  • ​What should I do with a soft start phase missing fault?
    062021-12

    ​What should I do with a soft start phase missing fault?

    快盈500个人主页In the debugging process, there is a soft start report phase failure, the soft starter fault light is on, the motor is not responding. The cause of the failure may be:a-start mode of power, the operat···

  • Five common starting modes of motor
    032021-12

    Five common starting modes of motor

    The most familiar electric equipment for electrical operators should be the motor. There are many ways to start the motor, including direct start, self coupling decompression start and y- Δ Step down···

  • Several common parameters of motor soft starter
    032021-12

    Several common parameters of motor soft starter

    Several common parameters of motor soft starter:(1) Start rampThe start ramp is the time from the soft starter start ramp (initial voltage) to full voltage. The ramp time should not be too long, as th···

  • Application of suowei inverter in electric submersible pump system
    032021-12

    Application of suowei inverter in electric submersible pump system

    快盈500个人主页The appearance of frequency converter has brought a revolution to the way of AC speed regulation. With the continuous improvement and development of frequency conversion technology in recent ten years···

  • Suowei Electric Co., Ltd. website revision success!
    282021-11

    Suowei Electric Co., Ltd. website revision success!

    Friends: In order to further improve the level of enterprise services, in 2019, the company has carried out a revision and upgrading of the website. At present, the company has completed the column de···